SR988C1 Solar Controller
Product Detailed
Related Categories:Solar Collectors
SR988C1 Solar Controller
1.power consupltion less than 3w
2.Trouble protection and Checking
3.ISO.CE Approved
SR988C1 Solar Controller
Main technical data | ||||||
Technical data | ||||||
Specification Parameter | ||||||
Appearance of controller 200mm×155mm×45mm | ||||||
Power supply AC230V±10% | ||||||
Power consumption < 3W | ||||||
Accuracy of temperature measuring ±2oC | ||||||
Range of collector sensor measuring -10~220oC | ||||||
Range of tank sensor measuring 0~100oC | ||||||
Suitable power of pump 9,≤ 200W | ||||||
Suitable power of electrical heater 1,≤ 1500W | ||||||
Inputs 2 x Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC), | ||||||
10 x NTC10K, B3950 sensor (≤ 135oC) for tank or pipe, | ||||||
(PVC cable ≤105oC), | ||||||
Outputs 9 relays for circulation pumps or 3-way electromagnetic valve | ||||||
1 relay for electrical heater | ||||||
Ambient temperature -10~50 oC | ||||||
Water proof grade IP40 |
Main functions | ||||||
SYSTME(SYS1~SYS12) | ||||||
DT O & DT F Temperature difference controlling the Solar circuit pump | ||||||
THET Timing heating | ||||||
EM Emergency collector temperature(emergency switch-off | ||||||
temperature of collector) | ||||||
CMX Maximum limited collector temperature(collector cooling function) | ||||||
CMN low temperature protection of collector | ||||||
CFR frost protection of collector | ||||||
SMX Maximum temperature of tank | ||||||
REC Tank re-cooling function | ||||||
MAX1 Maximum turnoff temperature (for solid fuel boiler, return heating, | ||||||
heat transferring between tanks) | ||||||
MIN1 Minimum turn-on temperature (for solid fuel boiler, return heating, | ||||||
heating transferring between tanks) | ||||||
DVWG Anti-Legionella function | ||||||
CIRC Temperature controlled hot water circulation pump | ||||||
nMIN Solar circulation pump speed adjusting(RPM speed controlling) | ||||||
OHQM Thermal energy measuring | ||||||
Priority logic of tank | ||||||
INTV Pump interval fucntion | ||||||
BYPR High temperature by-pass function(Tank temperature automatically | ||||||
adjusting) | ||||||
Holiday fucntion | ||||||
HND Manual mode | ||||||
PASS Password setting | ||||||
RSET Recovery to factory setting | ||||||
Manual Heating | ||||||
Temperature query function | ||||||
Memory Protection | ||||||
Anti-dry heating protection | ||||||
Screen protection | ||||||
Trouble protection |